Zhengzhou Protech
Home > News

High temperature furnace use skills and maintenance methods

High temperature is abbreviated as high temperature furnace. It is a necessary equipment for laboratory or factory analysis, measurement and research, high temperature burning and metal heat treatment. With the development of science and technology, high temperature is becoming more and more intelligent, and its operating temperature is also increasing, up to more than 2,000 degrees. Therefore, you must be careful when using a high-temperature muffle furnace to avoid burns. Let me share with you some tips and maintenance methods for high temperature muffle furnace.xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
1. Installation and use of high temperature muffle furnacexwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
1. The high temperature muffle furnace must be installed on the indoor flat workbench. The matching temperature controller should not be placed too close to the electric furnace to avoid vibration, and the room should be kept ventilated and dry, and the temperature should be lower than 40 ℃.xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
2. The high temperature muffle furnace electric furnace and temperature controller must be grounded reliably.xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
3. After the installation is completed, turn on the power supply, turn on the power switch of the controller, and set the temperature adjustment instrument to the required temperature. At this time, the green light of the instrument is on, indicating that the heating starts, and the ammeter generates a corresponding reading according to the power level, and adjusts the indication of the instrument. The temperature also rises at the same time. When the temperature rises to the set temperature, the adjustment instrument automatically cuts off the power supply, the red light is on, and the ammeter indication returns to "zero". The use of the high-temperature furnace means that the heating stops. Adjust the "red" "green" of the instrument and the indicator lights to work alternately to make the instrument reach a constant temperature state. During this process, if the electric furnace does not heat up or the instrument display is abnormal, you must immediately turn off the power and contact the manufacturer for communication to determine the problem and take appropriate measures.xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
4. After the high temperature muffle furnace completes the experimental work, first turn off the power supply, when the furnace temperature drops to a safe level, then open the furnace and take out the experimental materials.xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
2. Maintenance and maintenance of high temperature muffle furnacexwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
1. If the electric furnace does not heat up, then consider that there should be a problem with the heating element. First check whether the heating element is loose. If it is loose, plug it in and try it first. If it still does not heat up, it means that the heating element is faulty. . Then the heating element needs to be replaced with a new one. Taking the silicon molybdenum rod as an example, when replacing, first remove the protective cover at both ends and the silicon molybdenum rod chuck, then take out the damaged silicon carbon rod, and then replace the new silicon molybdenum rod.xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
The rod can be installed. However, the silicon molybdenum rod is a fragile material, so care must be taken when installing it.xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
2. If the electric furnace instrument display is abnormal, first debug it, if not, you can contact the manufacturer's technicians for video communication to guide the debugging. If the debugging is still unsuccessful, it means that the instrument is faulty, and a new instrument can be replaced.xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
3. Regularly check whether the connection of the connection part of the circuit system is good.xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
4. Correct use and standard operation, the maximum temperature of 1200 ℃ can not be used for a long time, avoid over-temperature and overload operation, and strictly prevent sudden rise and power failure and rapid cooling, so as to avoid damage to the furnace and electric heating wire.xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
5. As well as maintenance methods, it is strictly forbidden to directly enter the workpiece with high moisture, volatile matter, organic matter, etc. into the furnace for heating treatment.xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
6. It is strictly forbidden to put metal, glass and other high-temperature melting substances into the furnace for heating treatment without the crucible loaded.xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
7. Regularly check the condition of the electric heating element. If it is aging, broken or short-circuited, it should be repaired and replaced in time.xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
8. Frequently remove dust particles and scattered objects in the furnace to keep the furnace clean.
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
xwQMuffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac
 

Product