Power |
1.Voltage: Single-phase 208 - 240 VAC / 50/60Hz, (25 A breaker installed)7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 2.3 KW max.7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 3.Note: Power cable included but without the plug. Please install a plug by your own or click link below the picture to choose a plug according to your country or your lab requirement |
Working Temperature |
1.<= 1000 °C continuously7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 2.Max. 1100 °C, < 30 minutes7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 3.Temperature Uniformity: +/- 2°C |
Heating Rate |
1.Max. 20°C/ min7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 2.Recommended. 10°C/ min |
Heating Elements |
High-quality Ni-Cr-Al resistance wire |
Quartz Tube & Effective Heating |
1.Tube size: 8" O.D. x 7.5" I.D x 13.4" L. 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 2.Heating area: 7.5" ID x 8.5" Depth (7.6Liter)7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 3.Uniform Temperature zone: 4"Dia x 3.5" depth in center position within +/- 5ºC7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 4.The quartz tube is replaceable |
7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac Vacuum Flange7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac |
1.Stainless steel vacuum flange with dual high-temperature silicone O-rings at the front door with water colling ports7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 2.1/4 gas inlet & outlet included which allow continuous gas delivery during operation. A gas quartz tube (6.35mm O.D) is provided to reach the location of the sample and deliver reactive gas to the sample directly. 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 3.One 1/4 thermocouple feedthrough port allows a 1/4 O.D thermocouple probe to be inserted into the chamber and measure the temperature of the sample independently. (Thermocouple is optional. Click here to find one). Four probes electric resistance measurement feedthrough also is available upon request.7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 4.M15 x 1.5mm Thread for both 1/4" feedthrough7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 5.One bored Al2O3 foam refractory block (190Dia * 50mm) is provided.7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 6.K type 1/4" OD x 18" L thermocouple is included. 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 7.Gas Inlet Tube (O.D 6.35mm, I.D 4.0 mm, L 300mm) is included. 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 8.Mechanical Vacuum Gauge (included as standard accessory), which ranges from -0.1 to 0.15Mpa. |
Gas Inlet and Outlet & Water cooling7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac |
1.One gas purging inlet (1/4" hose adapter ) with a valve is on the left side of the furnace 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 2.The inert gas can be introduced into the chamber via the inlet for purging purposes. 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 3.If a continuous gas flow is needed, refer to the additional gas inlet and thermocouple probe below.7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 4.A water cooling jacket has been built inside the flange to protect the vacuum sealing O-tings. The inlet and outlet ports located on the left side of the furnace are used for connecting to a water chiller through two 12 mm Dia. polyurethane tubes (16L/minute water flow is required). |
Temperature Controller7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac |
1.NRTL certified digital temperature controller is included.7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 2.Proportional–integral–derivative control (PID control) and auto-tune function7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 3.30 segments programmed with ramping, cooling, and dwelling steps7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 4.Built-in over-temperature alarm and thermocouple failure alarm7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 5.+/- 1 ºC temperature control accuracy7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 6.THE Default DB9 PC communication port included for connecting to PC7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 7.Temperature Controller is available at the extra cost with +/-0.1°C accuracy. |
Options7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac |
1.Digital Pressure Gauge (optional) A gas-type independent(above 10mbar) digital vacuum gauge with a wide range between 3.8x10-5 to 1125 Torr.7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 2.You may choose a gas mixer to deliver multiple gasses with control over gas composition and flow rate. |
Options |
1.The sample holder is not provided with the furnace. You may Contact us to order the sample holder separately. 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 2.Optional Quartz Thermal Block is available upon request as the refractory block, which can help achieve a higher vacuum level and avoid potential contamination problems, please contact us order Quartz Thermal Block.7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 3.A 4-holes 1/4" Alumina Tube can be used for inserting 4 wires (e.g. Pt wires) through the holes for measuring the electrical properties at the high temperature at extra cost. |
7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac Vacuum Pressure7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac |
Vacuum Level is dependent on the vacuum pump used, connected pipe, interior refractory block's materials, etc. By using KFD25, stainless steel pipe, Kejia's two-stage mechanical pump, and KF25 Ball valve, the furnace can achieve vacuum levels below:7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 1.10-2 torr via mechanical pump within 30 minutes without thermal Block7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 2.10-4 torr via turbo-pump within 30 minutes with the Quartz Thermal Block at 900C7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac Optional:7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac The vacuum pump and pipe are not included, please contact us to order.7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac For achieving a higher vacuum level, a Turbopump is necessary.7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac Spare sealing O-ring is available at extra cost .7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac KF25 Right-Angle Valve for quick connection to KF25 Bellows. |
Overall Dimensions |
700mm(L) x 440mm(W) x 435mm(H) |
Net Weight |
80 kg |
Shipping Weight |
200 lbs |
Shipping Volume |
45"(L) x28"(W) x35"(H) |
7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac Warranty |
1.One year limited warranty with lifetime support (consumable parts such as processing tubes, and O-rings are not covered by the warranty.). 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 2.ATTENTION: Any damages caused by the use of corrosive and acidic gasses are not under the coverage of Kejia One Year Limited Warranty. |
Compliance |
CE Certified |
Warning 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac |
1.Tube furnaces with quartz tubes are designed for use under vacuum and at low-pressure < 0.2 bars 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 2.Attention: A two-stage pressure regulator must be installed on the gas cylinder to limit the pressure to below 3 PSI for safe operation. 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 3.Never heat the furnace while the gas release valve is closed when a positive pressure condition exists within the furnace chamber. 7a6Muffle Furnace,Tube Furnace,Vacuum Furnace,Atmosphere Furnac 4.Max. 1000°C is limited on all quartz tube furnaces to avoid the quartz tubes' deformation. |